Miller-electric Remote Operator Interface Instrukcja Użytkownika Strona 27

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 40
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 26
OM-217 834 Page 23
SECTION 6 SETTING SEQUENCE PARAMETERS
6-1. Sequence Parameters In A Program
. For more information on
Sequence mode, see Feeder
Set Up Push Button in Section
5-7.
Weld Time can only be set by using
an optional PDA with File
Management/WaveWriter software.
If time is set to zero in any timed
sequence, the sequence is skipped.
. Maximum IPM may actually be
lower depending on the process
and wire type selection.
Trigger
Pressed
Trigger
Released
Start
Time
Preflow
Weld
Crater
Time
Postflow
Start
Time
Time
PostflowCrater
Weld
Preflow
Sequence
End
Volts/Arc
Adjust
IPM Seconds
2. Postflow Off-5.0
1. Preflow Off-5.0
Sequence Parameters
3. Start
4. Crater
Off-5.0
Off-5.0
10.0-44.0/
0-99
40-1400
10.0-44.0/
0-99
40-1400
Przeglądanie stron 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 39 40

Komentarze do niniejszej Instrukcji

Brak uwag